4 Channels
FUNCTIONING
As soon as a surplus of production compared to consumption is detected, the energy is automatically directed in the following order:
1 - Supply of output 1 (S1) from the first Watts
2 - If output 1 is not connected or the device (water heater) does not consume, output 2 is powered from the first Watts
3 - As soon as the power indicated for TX1 is reached (addition of the energies delivered to S1 + S2 + energy still available), the transmitter sends the power supply signal of the TX1 output.
An adjustable time delay is applied to switching on and off: when TX1 is powered, it does not stop until after the time delay. When the power supply to TX1 is cut, it can only resume after the time delay. This is to avoid starting and stopping harmful to certain devices.
4 - If TX1 is powered and the energy still available is greater than the power of TX2, the transmitter sends the power signal to the TX2 output. An adjustable time delay is also applied.
5 - If energy remains available after supplying TX1, TX2 or both, outputs S1 then S2 are supplied so as not to be exported to the network.
"Boost" FUNCTION
Switching on the "Boost" function supplies the output concerned (S1 or S2) for 30 to 120 minutes and switches off the other output. Outputs TX1 and TX2 are switched off.
MAINS POWER FAILURE
The 4 outputs (S1, S2, TX1, TX2) are automatically cut off and when powered up again they will not be powered until the optimizer gives the order.
Installation with contactor
Installation with programmed clock
TECHNICAL CHARACTERISTICS
Rated voltage : 230VAC single phase 50Hz
Voltage range : 205 – 260VAC
Frequency range : 48 to 60 Hz
Maximum allowable current in measurement : 90A (20,000W at 220V)
Standby consumption : 0.05W (at 230VAC)
Transfer rate : 99.7% (at maximum power)
Maximum load : 600A for 10ms
Load S1 : adjustable from 100 to 3000W, resistive load only, variable output from 1% to 100%
Load S2 : adjustable from 100 to 3000W (0 if not used), resistive load only, output variable from 1% to 100%
Maximum current : 13A (output S1 or S2)
Routing accuary : 10 to 30W
Boost function : Adjustable from 30 minutes to 120 minutes of supply at full power to outputs S1 or S2
Maximum power per remote-controlled socket : 2400W resistive load, 1000W reactive load
Adjustable threshold per socket : 100W to 2400W resistive load, 100 to 1000W capacitive load (motor, pump, etc.). (0 if not used).
Time delay : Adjustable from 1 to 180 minutes when the sockets are switched on and off.
Operating temperature : 0 to 60°C
Storage temperature : –20 to +75°C
Humidity : 10 to 85% non-condensing. Indoor installation only
Insulation : Transformer: 2.5 kV - Optocouplers: 3.75 kV - Probe: 6 kV
Export Threshold : 0W
Maximum power dissipated at 3 Kw : 20W
Internal fuse : 250V 100mA
Remote control frequency : 433.92MHz
Range in free field : 40m
Dimensions : 15cm x 12cm x 3.5cm